MET-U1A
The INNOVATEST MET-U1A differs completely from traditional hardness testers. Instead of measuring the size of the indentation of the test sample using a microscope, it uses a diamond indentor mounted on a vibrating rod that presses on the test surface at a fixed load and then measures its hardness by applying ultrasonic vibrations and analyzing its damping effect. The technique is very reproducible which makes the MET-U1A a perfect tool for on-site measurements such as maintenance of large scale structures, vehicles, ships, steel towers, bridges, air planes. It is ideal for inspection of thin materials or difficult to get area such as crank shaft, gears and grooved areas.
  • Hardness measurements of metals and alloys on standardized hardness scales:
    Rockwell (HRC), Brinell (HB), Vickers (HV) and Shore (HSD)
  • Three additional scales H1, H2, H3 for calibration of selfdefined
    hardness scales
  • Rm scale for determination of tensile strength
  • Typically suitable for components that are inaccessable for dynamic hardness testers (small articles, structures with thin
    walls, pipes, reservoirs, steel sheets etc.)
  • Leaves no visible indent on the tested article surface (crankshafts necks, mirrored surface, knives)
Measuring principle  According to the UCI method (ultrasonic contact impendance principle)
Measuring range Rockwell C scale HRC 20-70
Brinell scale HB 75-650
Vickers scale HV 75-1000
Shore scale HSD 23-102
Tensile strength MPa 378-1736
Reproducibility Rockwell C scale HRC 1.5
Brinell scale HB 10
Vickers scale HV 12
Shore scale HSD 2
Tensile strength MPa 5%
Measurement results processing Computation of average value from the data stored in the memory; selective data deleting (for example, in case of doubt in the conducted measurements)
Display lighting Available
Display features Hardness scale, measured value, number of measurement, operation mode, archival number, battery charge indication, Auto-off after 150 sec.
Memory 100 readings, also stored when test is switched off
Surface roughness  
Convex/concave >5mm
Minimum specimen weight >0.01kg
Material thickness Probe without position accessories
>2mm Probe with position accessories >1mm
Penetration depth 0.03mm average
Probe operating life ±200000 measurement
Measuring force 14.7 N
Power supply AC mains, V / Hz100-240 / 50-60
Batteries AA, 1.2V (4pcs)
Consumed power <3.0VA
Battery life Without lighting 16 hours
With lighting 8 hours
Battery charging time 8 hours
Transportation & storage temperature -35°C ... +60°C
Operating environment Relative humidity 30% ... 80%
Overall size Gauge 180 x 80 x 42.4mm
Probe 160 / 25mm / ø7mm & -35°C ... +60°C
MET-U1A Ultrasonic portable hardness tester
  • Main unit
  • U1 ultrasonic probe
  • Power unit
  • Batteries AA (4pcs) NiMh
  • Carrier bag
  • INNOVATEST® certificate
  • User and installation manual
Related downloads
Related pictures
Optional accessories
  • Hardness reference test blocks
  • Precision holding fixture for probe
  • Battery operated grinder
  • Changeable headpiece to probe
  • Probe stand